Skip to Main content Skip to Navigation
Journal articles

Planck 2013 results. VI. High Frequency Instrument data processing

P. A. R. Ade N. Aghanim 1 C. Armitage-Caplan M. Arnaud 2 M. Ashdown F. Atrio-Barandela J. Aumont 1 C. Baccigalupi A. J. Banday 3 R. B. Barreiro E. Battaner K. Benabed 4 A. Benoît 5 A. Benoit-Lévy 4 J.-P. Bernard 3 M. Bersanelli P. Bielewicz 3 J. Bobin 2 J. J. Bock J. R. Bond J. Borrill F. R. Bouchet 4 F. Boulanger 1 J. W. Bowyer M. Bridges M. Bucher 6 C. Burigana J.-F. Cardoso 6, 4 A. Catalano 7, 8 A. Chamballu 9, 1, 2 R.-R. Chary X. Chen H. C. Chiang L.-Y Chiang P. R. Christensen S. Church D. L. Clements S. Colombi 4 L. P. L. Colombo C. Combet 7 F. Couchot 10 A. Coulais 8 B. P. Crill A. Curto F. Cuttaia L. Danese R. D. Davies R. J. Davis P. De Bernardis A. De Rosa G. De Zotti J. Delabrouille 6 J.-M. Delouis 4 F.-X. Désert 11 C. Dickinson J. M. Diego H. Dole 12, 1 S. Donzelli O. Doré M. Douspis 1 J. Dunkley X. Dupac G. Efstathiou T. A. Enßlin H. K. Eriksen F. Finelli O. Forni 3 M. Frailis A. A. Fraisse E. Franceschi S. Galeotta K. Ganga 6 M. Giard 3 G. Giardino D. Girard 7 Y. Giraud-Héraud 6 J. González-Nuevo K. M. Górski S. Gratton A. Gregorio A. Gruppuso J. E. Gudmundsson F. K. Hansen D. Hanson D. Harrison G. Helou S. Henrot-Versillé 10 O. Herent 4 C. Hernández-Monteagudo D. Herranz S. R. Hildebrandt E. Hivon 4 M. Hobson W. A. Holmes A. Hornstrup Z. Hou W. Hovest K. M. Huffenberger G. Hurier 1, 7 A. H. Jaffe T. R. Jaffe 3 W. C. Jones M. Juvela E. Keihänen R. Keskitalo T. S. Kisner R. Kneissl J. Knoche L. Knox M. Kunz 1 H. Kurki-Suonio Guilaine Lagache 1 J.-M. Lamarre 8 A. Lasenby R. J. Laureijs C. R. Lawrence M. Le Jeune 6 R. Leonardi C. Leroy 3, 1 J. Lesgourgues M. Liguori P. B. Lilje M. Linden-Vørnle M. López-Caniego P. M. Lubin J. F. Macías-Pérez 7 C. J. Mactavish B. Maffei N. Mandolesi M. Maris F. Marleau D. J. Marshall 2 P. G. Martin E. Martínez-González S. Masi M. Massardi S. Matarrese F. Matthai P. Mazzotta P. Mcgehee P. R. Meinhold A. Melchiorri F. Melot 7 L. Mendes A. Mennella M. Migliaccio S. Mitra M.-A. Miville-Deschênes 1 A. Moneti 4 L. Montier 3 G. Morgante D. Mortlock S. Mottet 4 D. Munshi J. A. Murphy P. Naselsky F. Nati P. Natoli C. B. Netterfield H. U. Nørgaard-Nielsen C. North F. Noviello D. Novikov I. Novikov François Orieux 4 S. Osborne C. A. Oxborrow F. Paci L. Pagano F. Pajot 1 R. Paladini D. Paoletti F. Pasian G. Patanchon 6 O. Perdereau 10 L. Perotto 7 F. Perrotta F. Piacentini M. Piat 6 E. Pierpaoli D. Pietrobon S. Plaszczynski E. Pointecouteau 3 G. Polenta N. Ponthieu 11, 1 J. P. Rachen L. Popa T. Poutanen G. W. Pratt 2 G. Prézeau I. Ristorcelli 3 S. Prunet 4 J.-L. Puget 1 B. Racine 6 W. T. Reach R. Rebolo M. Reinecke M. Remazeilles 6, 1 C. Renault 7 S. Ricciardi T. Riller G. Rocha C. Rosset 6 G. Roudier 6, 8 M. Rowan-Robinson B. Rusholme L. Sanselme 7 D. Santos 7 A. Sauvé 3 G. Savini D. Scott E. P. S. Shellard L. D. Spencer J.-L. Starck 2 V. Stolyarov R. Stompor 6 R. Sudiwala F. Sureau 2 D. Sutton A.-S. Suur-Uski J.-F. Sygnet 4 J. A. Tauber D. Tavagnacco S. Techene 4 L. Terenzi M. Tomasi M. Tristram 10 M. Tucci 10 G. Umana L. Valenziano J. Valiviita B. Van Tent 13 L. Vibert 1 P. Vielva F. Villa N. Vittorio L. A. Wade B. D. Wandelt 4 S. D. M. White D. Yvon 9 A. Zacchei A. Zonca
Abstract : We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (hereafter HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857 GHz with an angular resolution ranging from 9.7 to 4.6 arcmin. The detector noise per (effective) beam solid angle is respectively, 10, 6, 12 and 39 microKelvin in HFI four lowest frequency channel (100--353 GHz) and 13 and 14 kJy/sr for the 545 and 857 GHz channels. Using the 143 GHz channel as a reference, these two high frequency channels are intercalibrated within 5% and the 353 GHz relative calibration is at the percent level. The 100 and 217 GHz channels, which together with the 143 GHz channel determine the high-multipole part of the CMB power spectrum (50 < l <2500), are intercalibrated at better than 0.2 %.
Complete list of metadatas

Cited literature [47 references]  Display  Hide  Download

https://hal.archives-ouvertes.fr/hal-01225863
Contributor : François Orieux <>
Submitted on : Tuesday, March 10, 2020 - 4:54:37 PM
Last modification on : Thursday, July 23, 2020 - 9:48:05 AM
Document(s) archivé(s) le : Thursday, June 11, 2020 - 3:04:12 PM

File

1303.5067.pdf
Files produced by the author(s)

Identifiers

Citation

P. A. R. Ade, N. Aghanim, C. Armitage-Caplan, M. Arnaud, M. Ashdown, et al.. Planck 2013 results. VI. High Frequency Instrument data processing. Astronomy and Astrophysics - A&A, EDP Sciences, 2014, 571, pp.A6. ⟨10.1051/0004-6361/201321570⟩. ⟨hal-01225863⟩

Share

Metrics

Record views

534

Files downloads

555